01 A complete quality system
Quality Beyond 99%
HPLC purity is important, but it is only one part of the analytical picture. Our testing process uses multiple analytical methods to answer different questions about identity, purity, peptide content, and applicable contaminants.
Identity
Is the supplied material the expected compound?
Mass spectrometry measures the material’s molecular mass and compares it with the expected compound, helping confirm its identity.
Purity
How much of the detected peptide material is the principal compound?
HPLC separates the components in a sample, allowing the principal compound to be measured relative to other detected material.
Peptide content
How much peptide is actually present?
Quantitative analysis measures the amount of peptide present, providing a separate check from purity percentage alone.
Contaminants
Are specified contaminants within acceptable limits?
Testing may include heavy metals, bacterial endotoxins, and targeted contaminant screening where applicable.
02 Defined release specifications
A batch is not released because the report “looks good.”
It is reviewed against defined release criteria. If it does not meet our standards, it does not ship.
220+
Total tests
99.64%
Average purity
10.6%
Average overfill
1
Confirmed molecular identity
The supplied material must match the expected compound based on mass spectrometry.

Measured by mass spectrometry
2
Ultra-high purity
Each batch must demonstrate at least 99% chromatographic purity.

Measured by HPLC
3
Consistent peptide content
Measured peptide content must be no more than 10% below the stated amount. Overfill is acceptable.
≥ 90%
of stated
peptide content
Average across tested batches:
110.6%
4
Contaminant free
Where applicable, batches must meet our laboratory limits for specified contaminants.
| Parameter | Specification | Result |
|---|---|---|
| Heavy Metals | ≥ 0.5ppm | Pass |
| Endotoxin | ≥ 0.25 Eu/mg | Pass |
| Fentanyl | Not detected | Pass |
Additional targeted screening where applicable.
03 Batch release process
From material to released research product.
It is reviewed against defined release criteria. If it does not meet our standards, it does not ship.
Sampled
Representative samples are selected from each production lot
Independently Tested
Samples are submitted to a qualified third-party laboratory for analytical testing
Reviewed
Analytical results are reviewed against our internal release specifications
Published
Results and supporting documentation are published online before shipment
Release Decision
Only material meeting our standard is made available for sale
04 Independent third-party verification
Our suppliers do not grade their own work


Honest Peptide contracts qualified, third-party laboratories for testing. We will never rely on testing performed by our suppliers.
05 Independent testing. Direct verification.
Verify your COA
Review the analytical results and verify your Certificate of Analysis (COA) directly through the issuing laboratory. Follow the steps below to locate your report and confirm it matches the laboratory’s record.
1
Find your product’s COA
Locate the product in our COA Library or on its product page. Open the COA for the relevant batch or lot.
2
Review the results
Inspect the reported analytical values and testing details.
3
Identify the laboratory
Find the name of the laboratory that issued the COA: Janoshik, Freedom Diagnostics, or Chromate.
4
Open the laboratory’s lookup page
Select the corresponding link below.
5
Locate the analytical report
Follow the issuing laboratory’s instructions to locate and verify the analytical report.
6
Confirm the report matches
Compare the laboratory’s record with the COA from our website. Check that the report identifiers, sample details, and analytical results match.